Chapter 3 - IP Address and Network Configuration Services
50
Mediatrix 4100
MGCP Call Agent
The ipAddressConfigMgcpCallAgent group provides the configuration necessary for contacting a MGCP call
agent.
To select the MGCP Call Agent configuration source:
1. In the ipAddressConfig folder, locate the mgcpCASelectConfigSource variable (under the
ipAddressConfigMgcpCallAgent group).
2. Set this variable to either static or dhcp (vendor/site specific option).
3. Restart the Mediatrix 4100 so that the changes may take effect.
NCS Call Agent
The ipAddressConfigNcsCallAgent group provides the configuration necessary for contacting a NCS call
agent.
To select the NCS Call Agent configuration source:
1. In the ipAddressConfig folder, locate the ncsCASelectConfigSource variable (under the
ipAddressConfigNcsCallAgent group).
2. Set this variable to either static or dhcp (vendor/site specific option).
3. Restart the Mediatrix 4100 so that the changes may take effect.
Table 35: MGCP Call Agent Source
Variable Default Static Value DHCP Source
mgcpCAHost “192.168.0.10” Use option specified in variable
mgcpCADhcpSiteSpecificCode, bytes 0-3.
If not specified (0), use option 43, sub-option
207, bytes 0-3.
mgcpCAPort 2727 Use option specified in variable
mgcpCADhcpSiteSpecificCode, bytes 4-5.
If not specified (0), use option 43, sub-option
207, bytes 4-5. If bytes 4-5 are not present, use
the default static value.
Table 36: NCS Call Agent Source
Variable Default Static Value DHCP Source
ncsCAHost “192.168.0.10” Use option specified in variable
ncsCADhcpSiteSpecificCode, bytes 0-3.
If not specified (0), use option 43, sub-option
210, bytes 0-3.
ncsCAPort 2727 Use option specified in variable
ncsCADhcpSiteSpecificCode, bytes 4-5.
If not specified (0), use option 43, sub-option
210, bytes 4-5. If bytes 4-5 are not present, use
the default static value.